Flow-X: Testing and Approvals
Besides the performance of the measurement hardware, the flexibility and power of the software, another key factor on usability for a flow computer includes its full conformance to internationally recognized standards and regulations.
An overview of approvals for the Flow-X series is given below.
Introduction
Since the introduction of MID in October 2006 only one approval applies for gas and liquid flow computers in all the EU and EFTA countries.
An MID approval is hence valid in 30 European countries, and forms a sound basis for additional tests and approvals in non-EU countries.
In a market where existing products sometimes have a hard time keeping up with legislation and compliance to new international metrology, we are proud to inform you that we have recently passed all MID certification tests for both gas and liquid applications without any exceptions whatsoever.
|
|
|
|
Harry Kok, CEO of Spirit IT said:
“Today marks a significant milestone in our company’s history and a new benchmark for the oil and gas measurement industry. In a market where the available devices have failed to keep pace with developments in modern electronics and the information technology demands of the users, Spirit IT has produced a true leading edge product that answers the markets needs for today and the flexibility for the future. Our Engineers and Partners have delivered a truly remarkable product from its unrivaled analog accuracy to its unmatched digital signal processing features, storage and software flexibility. I herewith thank all those involved in the development and our customers who’s encouragement and feedback have brought us to this remarkable point."
Achieved approvals
Below we present the results of various certification processes of our Flow-X series of flow computers by various internationally recognised testing authorities, including the Dutch Metrology Institute NMi.
Appertaining certificates are available for download for our customers at request.
Click [here] to revert to our library section of our website for the downloading of certificates and test reports.
A complete list of appertaining certificates, documents and test reports are available at request. The metrology approvals of our Flow-X approvals include (more will follow in the near future):
|
# |
Directive/Standard |
Description of Standard, Directive, or Test procedure |
Approval |
|---|---|---|---|
| 1 | CE | Marking as per Conformité Européene, Directive 93/68/EEC. Declaration of conformity. |
Yes |
| 2 | MID | Measuring Instruments Directive MID, Annex MI-002 and Annex MI-005. |
Yes |
| 3 | EN 12405-1 | European Standard for Gas meters and Gas-volume electronic conversion devices; part of MID. |
Yes |
| 4 | OIML R117-1 | Organisation Internationale de Metrologie Legale, Dynamic measuring systems for liquids other than water standard, Edition 2007; part of MID. |
Yes |
| 5 | WELMEC 7.2 | Software Guide - Measuring Instruments Directive 2004/22/EC; included in MID. |
Yes |
| 6 | EN 61326-1997 | Electromagnetic Compliance specification for Industrial locations; included in MID. |
Yes |
| 7 | EN 55011 | Electromagnetic Compliance specification; included in MID. |
Yes |
For the above approvals, tests were conducted to the flow computer, in accordance with the following IEC test procedure standards:
|
# |
Standard |
Description of Test Procedure |
Compliant |
|---|---|---|---|
| 1 | IEC 60068-2-1 | Cold test | Yes |
| 2 | IEC 60068-2-2 | Dry Heat | Yes |
| 3 | IEC 60068-2-3 | Damp heat steady state | Yes |
| 4 | IEC 60068-2-31 | Drop and topple | Yes |
| 5 | IEC 60068-2-36 | Shock resistance | Yes |
| 6 | IEC 60654-2 | DC mains voltage variation | Yes |
| 7 | IEC 61000-4-29 | Voltage dips, short interruptions and voltage variations on DC mains power | Yes |
| 8 | IEC 61000-4-2 | Electrostatic discharge immunity 8 kV direct contact, 15 kV indiirect contact | Yes |
| 9 | IEC 61000-4-3 | Radiated, radio-frequency, electromagnetic field immunity | Yes |
| 10 | IEC 61000-4-4 | Electrical fast transient/burst immunity on DC mains lines | Yes |
| 11 | IEC 61000-4-4 | Electrical fast transient/burst immunity on signal, data and control lines | Yes |
| 12 | IEC 61000-4-5 | Surges on DC mains lines | Yes |
| 13 | IEC 61000-4-5 | Surges on signal, data and control lines | Yes |
| 14 | IEC 61000-4-6 | Immunity to conducted radio-frequency fields | Yes |
| 15 | IEC 61000-4-17 | Ripple on DC input power ports | Yes |





Previous: